# Custom Config file for Activity Level From Physical Activity Metrics

  • Save this file as customConfig.xml
  • Copy to C:\Program Files (x86)\movisens\DataAnalyzer
  • Edit to you needs
<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!-- copy to C:\Program Files (x86)\movisens\DataAnalyzer -->
<!-- choose the physical activity metric you want to use by commenting/uncommenting the lines with "selectedPaMetricNameForActLevel"-->
<!-- specify the correct values for the cutpoints to be used -->

<config>
   <parameters>
    <string name = "selectedPaMetricNameForActLevel" value = "paMetricMovementAccelerationIntensity"/>
    <!--<string name = "selectedPaMetricNameForActLevel" value = "paMetricMeanAmplitudeDeviation"/>-->
    <!--<string name = "selectedPaMetricNameForActLevel" value = "paMetricEuclideanNormMinusOne"/>-->
    
    <double name = "cutpointActivityLevelInactiveLight" value = "0.1305"/>
    <double name = "cutpointActivityLevelLightModerate" value = "0.286"/>
    <double name = "cutpointActivityLevelModerateVigorous" value = "0.7605"/>
   </parameters>
</config>
Last Updated: 4/20/2023, 2:58:58 PM